LOCK BEWEGT // LOCK MOVES 16 EWA CHAPTER 03 – POWER DRIVES 2024 | 01 EWA 10 // Power drive 50 –90 Nm > Extremely quiet, self-locking worm gear units with long service life, zero-maintenance. > Universal mounting with standard at back or optional on side left (symmetrical). > Installed precision END 20 gear limit switch for 580 shaft revolutions (microswitch in cURus). > Optional LSC 40.10 AC or DC control unit incl. additional limit switch. Wire up using a 7-core cable. > Quality motors with multi-range voltage (IEC 38) for 50 Hz (400 V 3~ // 230 V 1~). IP55, Th.Cl.F, S3-40 %. > A coil protection contact is integrated in all single-phase motors. Turnkey with cable. > Round shaft We 06, 90 Nm version also available with hex shaft We 66. Options when using the END 20.20: > On 60 Hz versions, the END 20.40 additional limit switch is standard equipment. > Additional limit switch END 20.40. > Position sensor PAR 06 or PAR 10. Options when using LSC 40.10: > LPR 02 position sensor for analogue signal, LPR 04 for digital signal.